Analisis Resiko Yang Mempengaruhi Tingkat Air Ketel Uap Dari Imbibisi Air Kondensat PG. Pesantren Baru Dengan Menggunakan Metode FMEA Dan FTA

Saiful Rowi(1*), Heribertus Budi Santoso(2), Imam Safi'i(3),

(1) Fakultas Teknik, Universitas Kadiri.
(2) Fakultas Teknik, Universitas Kadiri.
(3) Fakultas Teknik, Universitas Kadiri.
(*) Corresponding Author

Abstract


PG. Pesantren Baru is one of the industrial companies that produce sugar for the needs of people in Kediri City and national. The purpose of this research is to know the factors that inhibit the rate of supply of dew water (condensate water) to the boiler and how it is handled using Failure Mode and Effect Analysis (FMEA) and Fault Tree Analysis (FTA) methods. The scope and limitation of problems on this research is only done on boiler stations and more leads to dew water supply (condensate water) on the boiler machine Yoshimine II. The data used in this research is the primary data and secondary data from the company. With data collection techniques include observation, interviews and library studies. From the research results obtained 5 constraints that have been identified by the FMEA method. From 5 constraints gained 2 top events that have occurred during the operation process in the area of water flow imbibisi at the grind station PG. Pesantren Baru in 2018-2019. The first ranking is on the constraints of the pump to distribute the water Imbibisi to the APK tank suffered damage with RPN at 18. The second ranking is on the obstacles of the water crust many are attached to the wall pipe evaporation body with RPN at 8.


PG. Pesantren Baru merupakan salah satu perusahaan industri yang memproduksi gula untuk kebutuhan masyarakat Kota Kediri maupun nasional.Tujuan dari penelitian ini untuk mengetahui faktor- faktor yang menghambat laju suplai air embun (air kondensat) ke ketel uap beserta cara penanganannya dengan menggunakan metode Failure Mode and Effect Analysis (FMEA) dan Fault Tree Analysis (FTA). Adapun ruang lingkup dan batasan masalah pada penelitian ini hanya dilakukan pada stasiun boiler dan lebih mengarah ke suplai air embun (air kondensat) pada mesin boiler Yoshimine II.Dari hasil penelitian didapat hasil 5 kendala-kendala yang sudah teridentifikasi dengan metode FMEA, yaitu pipa di dalam tanki badan penguapan bocor dengan nilai RPN 6, kerak nira menempel di dinding pipa badan penguapan dengan nilai RPN 8, pompa pada badan penguapan rusak nilai RPN 18, air tanki apk mengalami overcapacity dengan nilai RPN 4, sambungan pipa menuju tanki apk mengalami kerenggangan dengan nilai RPN 4. 2 nilai RPNtertinggi dari hasil 5 kendala-kendaladigunakan sebagai 2 top event dalam menganalisa FMEA. Hasil dari FTA menunjukkan 4 basic event, yaitu as penggerak tidak center, bearing rusak, rentang waktu perawatan lama, pemakaian terlalu over.


Keywords


Failure Mode and Effect Analysis; Fault Tree Analysis; Risk Priority Number

Full Text:

PDF

References


AIAG & VDA, AIAG FMEAAV-1 AIAG & VDA FMEA Handbook, 1st ed. AIAG & VDA, 2020.

D. U. M. Rohmah, W. A. P. Dania, and I. A. Dewi, “Risk Measurement of Supply Chain Organic Rice Product Using Fuzzy Failure Mode Effect Analysis in MUTOS Seloliman Trawas Mojokerto,” Agric. Agric. Sci. Procedia, 2015, doi: 10.1016/j.aaspro.2015.01.022.

L. N. Huda, “Analisis Kualitas Produk Minuman Guna Meningkatkan Performansi Jumlah Produksi Dengan Metode Fmea (Failure Mode And Effects Analysis),” Talent. Conf. Ser. Sci. Technol., 2018, doi: 10.32734/st.v1i2.292.

D. I. Situngkir, G. Gultom, and D. R. S. Tambunan, “Pengaplikasian FMEA untuk Mendukung Pemilihan Strategi Pemeliharaan pada Paper Machine,” J. Tek. Mesin, vol. Vol. V, No, no. 2, pp. 1–5, 2019.

N. B. Puspitasari and A. Martanto, “Penggunaan FMEA Dalam Mengidentifikasi Resiko Kegagalan Proses Produksi Sarung Alat Tenun Mesin,” Tek. Ind., vol. 9 (2), pp. 93–98, 2014.

M. R. Akbar, A. Subekti, and M. R. Dhani, “Identifikasi Bahaya Dengan Menggunakan Metode Fmea Pada Mesin Evaporator Di Pabrik Gula,” Proceeding 2nd Conf. Saf. Eng. Its Appl., no. 2581, pp. 779–782, 2018.

H. P. Bloch, “Root Cause Failure Analysis,” in Petrochemical Machinery Insights, 2017.

N. Metasari, “Quality Engineering,” Wordpress, 2014. .

A. Sutrisno, I. Gunawan, and S. Tangkuman, “Modified Failure Mode and Effect Analysis (FMEA) Model for Accessing the Risk of Maintenance Waste,” Procedia Manuf., vol. 4, no. Iess, pp. 23–29, 2015, doi: 10.1016/j.promfg.2015.11.010.

I. Sumaiya Thaseen and C. Aswani Kumar, “Intrusion detection model using fusion of chi-square feature selection and multi class SVM,” J. King Saud Univ. - Comput. Inf. Sci., vol. 29, no. 4, pp. 462–472, 2017, doi: 10.1016/j.jksuci.2015.12.004.

N. R. Anugrah, L. Fitria, and A. Desrianty, “Usulan Perbaikan Kualitas Produk Menggunakan Metode Fault Tree Analysis (FTA) Dan Failure Mode and Effect Analysis,” Reka Integr., pp. 146–157, 2019.

I. Setyadi, “Analisis Penyebab Kecacatan Celana Jeans dengan Menggunakan Metode Fault Tree Analysis (FTA) dan Failure Mode and Effect Analysis (FMEA) di CV Fragile Din Co,” Univeristas Widyatama, Bandung, 2013.

Z. Arifin, “Kriteria Instrumen dalam suatu Penelitian,” J. Theorems (the Orig. Res. Math., 2017.

Suryana, Metodologi Penelitian : Metodologi Penelitian Model Prakatis Penelitian Kuantitatif dan Kualitatif. 2010.

Anggads, “Boiler sebagai Pemanas Air,” blogspot.com, 2016. .

Insinyoer, “Prinsip Kerja Boiler,” Insinyoer.com, 2018. .

I. K. Swarjana, “Variabel Penelitian,” J. Progr. Stud. Pendidik. Guru Raudhatul Athfal ISSN 2338-2163 - Vol. 05, vol. 05, p. 41, 2018.

A. Heryana, “Kerangka Teori, Kerangka Konsep, Variabel Penelitian, Dan Hipotesis Penelitian (Dalam Penelitian Kuantitatif),” Metodol. Penelit., 2015.

A. R. Widya, “Peningkatan Efektivitas Mesin Power Press 60 T Dengan Menggunakan Analisa Reliability Centered Maintenance,” vol. 1, no. 2, pp. 99–107, 2017.

L. N. Widyastuti, H. Suliantoro, and R. Rumita, “Analisis Gangguan Sistem Transmisi Listrik Menggunakan Metode Root Cause Analysis (Rca),” Ind. Eng. Online J., vol. 3, no. 3, 2014.

N. A. Wessiani and F. Yoshio, “Failure mode effect analysis and fault tree analysis as a combined methodology in risk management,” {IOP} Conf. Ser. Mater. Sci. Eng., vol. 337, p. 12033, Apr. 2018, doi: 10.1088/1757-899x/337/1/012033.

M. T. Hidayat and R. Rochmoeljati, “Perbaikan Kualitas Produk Roti Tawar Gandeng Dengan Metode Fault Tree Analysis ( FTA ) Dan Failure Mode And Effect Analysis ( FMEA ) Di Pt . XXZ,” Juminten J. Manaj. Ind. dan Teknol., vol. 01, no. 04, pp. 70–80, 2020.

M. Sayuti, Muhammad, and M. S. Rifa’i, “Evaluasi Manajemen Perawatan Mesin Dengan Menggunakan Metode Reliability Centered Maintenance Pada PT. Z,” MIEJ J., vol. 2, no. 1, pp. 9–13, 2013.

D. F. Mayangsari, H. Adianto, and Y. Yuniati, “Usulan Pengendalian Kualitas Produk Isolator Dengan Metode Failure Mode and Effect Analysis (Fmea) Dan Fault Tree Analysis (Fta),” Tek. Ind. Nas. Bandung, vol. 3, no. 2, pp. 81–91, 2015.




DOI: http://dx.doi.org/10.30737/jurmatis.v3i1.1402

DOI (PDF): http://dx.doi.org/10.30737/jurmatis.v3i1.1402.g1313

Article Metrics

Abstract view : 318 times
PDF - 253 times

Refbacks

  • There are currently no refbacks.


Copyright (c) 2021 JURMATIS : Jurnal Ilmiah Mahasiswa Teknik Industri

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.