The foundation is an important building structure in the field of construction because it functions as the support of a building. The foundation must be planned appropriately to maintain the stability of the building. Strauss foundation is one type of foundation that is used to carry the burden if hard soil that has a strong carrying capacity is very deep from the ground surface. This study aims to calculate the carrying capacity of the Strauss foundation using the Meyerhof method. To estimate the carrying capacity of the soil, field testing is carried out using a CPT (Cone Penetration Test). The results of the analysis show that the carrying capacity of the deepest shallow foundation is 2 meters with an ultimate carrying capacity of 188 kg. While the carrying capacity of foundations in the depth of 3 to 5 meters. The most efficient result by Meyerhof's calculation was the number of poles as much as 2 at a depth of 4 meters with a pile group capacity of 74.13 tons, greater than the maximum load (69.42 tons)

Keywords: Carrying capacity, CPT (Cone Penetration Test), Strauss Foundation, Meyerhof.


Pondasi merupakan struktur bangunan yang penting dalam bidang konstruksi karena berfungsi sebagai penompang sebuah bangunan. Pondasi harus direncanakan dengan tepat untuk menajaga kestabilan bangunan. Pondasi strauss merupakan salah satu jenis pondasi yang digunakan untuk memikul beban apabila tanah keras yang mempunyai daya dukung yang kuat letaknya sangat dalam dari permukaan tanah. Penelitian ini bertujuan untuk menghitung daya dukung tanah pondasi strauss menggunakan metode Meyerhof. Untuk memperkirakan daya dukung tanah dilakukan pengujian lapangan dengan menggunakan CPT (Cone Penetration Test). Hasil analisis menunjukkan bahwa daya dukung pondasi dangkal terdalam pada  2 meter dengan daya dukung ultimit 188 kg. Sedangkan daya dukung pondasi dalam terdapat pada kedalaman 3 hingga 5 meter. Hasil paling efisien dengan perhitungan Meyerhof didapat jumlah tiang sebanyak 2 pada kedalaman 4 meter dengan kapasitas kelompok tiang yaitu 74.13 ton, lebih besar dibandingkan dengan beban maksimum (69.42 ton)

 

Kata kunci : Daya dukung, CPT (Cone Penetration Test ), Pondasi Strauss, Meyerhof.



References

A. Yusti, “Analisis Daya Dukung Pondasi Tiang Pancang Diverifikasi Dengan Hasil Uji Pile Driving Analyzer Test Dan Capwap,†Fropil, vol. 2, no. 1, pp. 19–31, 2014.

J. Tambunan, “Studi Analisis Daya Dukung Pondasi Tiang Pancang,†J. Ranc. Sipil, vol. 1, no. 1, pp. 21–30, 2012.

B. Chairullah, “Analisa Daya Dukung Pondasi Dengan Metoda SPT, CPT, DAN MEYERHOF Pada Lokasi Rencana Konstruksi PLTU Nagan Raya Provinsi Aceh,†vol. 3, no. 1, pp. 15–24, 2013.

R. Katzenbach, S. Leppla, H. Ramm, M. Seip, and H. Kuttig, “Design and construction of deep foundation systems and retaining structures in urban areas in difficult soil and groundwater conditions,†Procedia Eng., vol. 57, pp. 540–548, 2013.

F. Fahriani and Y. Apriyanti, “Analisis Daya Dukung Tanah Dan Penurunan Pondasi Pada Daerah Pesisir Pantai Utara Kabupaten Bangka,†Forum Prof. Tek. Sipil, vol. 3, no. 2, pp. 89–95, 2015.

H. Zhong and M. Yang, “Dynamic effect of foundation settlement on bridge-vehicle interaction,†Eng. Struct., vol. 135, pp. 149–160, 2017.

Z. Arifin, “Komparasi Daya Dukung Aksial Tiang Tunggal Dihitung Dengan Beberapa Metode Analisis Tesis,†pp. 1–126, 2007.

M. S. Zazkya Fitri Sylvarez, Tri Indra Wijaksana, S.Sos., “Analisa Daya Dukung Pondasi Bore Pile dengan Menggunakan Metode Analitis (Studi Kasus Proyek Manhattan Mall dan Condominium),†e-Proceeding Manag. ISSN 2355-9357, vol. 3, no. 1 April, pp. 477–484, 2016.

J. Pagehgiri, “ANALISIS PENGGUNAAN PONDASI MINI PILE DAN PONDASI BORPILE TERHADAP BIAYA DAN WAKTU PELAKSANAAN PEMBANGUNAN RUANG KELAS SMPN 10 DENPASAR Juniada Pagehgiri,†vol. 8, no. 1, 2015.

P. N. Lhokseumawe, K. Pengantar, rahayu deny danar dan alvi furwanti Alwie, A. B. Prasetio, and R. Andespa, “ANALISA DAYA DUKUNG PONDASI TIANG PANCANG PADA PROYEK PEMBANGUNAN GEDUNG KANWIL DJP DAN KPP SUMBAGUT I JALAN SUKA MULIA MEDAN,†J. Ekon. Vol. 18, Nomor 1 Maret201, vol. 2, no. 1, pp. 41–49, 2010.

R. Rajapakse, “Shallow Foundation Fundamentals,†Geotech. Eng. Calc. Rules Thumb, pp. 71–75, 2008.

M. Hjiaj, A. V. Lyamin, and S. W. Sloan, “Bearing capacity of a cohesive-frictional soil under non-eccentric inclined loading,†Comput. Geotech., vol. 31, no. 6, pp. 491–516, 2004.

R. Rajapakse, “Bearing capacity computation (general equation for cohesive and noncohesive soils),†Geotech. Eng. Calc. Rules Thumb, pp. 95–133, 2016.

Q. Chen and M. Abu-Farsakh, “Ultimate bearing capacity analysis of strip footings on reinforced soil foundation,†Soils Found., vol. 55, no. 1, pp. 74–85, 2015.

J. K. Lee, S. Jeong, and S. Lee, “Undrained bearing capacity factors for ring footings in heterogeneous soil,†Comput. Geotech., vol. 75, pp. 103–111, 2016.

N. Djarwanti and G. Maharani, “Komparasi Nilai Daya Dukung Tiang Tunggal Pondasi Bor Menggunakan Data SPT , dan Hasil Loading Test pada Tanah Granuler,†no. September, pp. 720–725, 2015.

U. Jusi, “Analisa Kuat Dukung Pondasi Bored Pile Berdasarkan Data Pengujian Lapangan (Cone Dan N-Standard Penetration Test),†SIKLUS J. Tek. Sipil, vol. 1, no. 2, pp. 50–82, 2015.

T. Matsumoto, L. T. Phan, A. Oshima, and S. Shimono, “Measurements of driving energy in SPT and various dynamic cone penetration tests,†Soils Found., vol. 55, no. 1, pp. 201–212, 2015.

E. S. Randyanto, “Menggunakan Metode Statik Dan Calendring Studi Kasus : Proyek Pembangunan Manado Town Square 3,†vol. 3, no. 9, pp. 631–643, 2015.

M. H. Baziar, A. Kashkooli, and A. Saeedi-Azizkandi, “Prediction of pile shaft resistance using cone penetration tests (CPTs),†Comput. Geotech., vol. 45, pp. 74–82, 2012.

A. J. Lutenegger and D. J. Degroot, “SETTLEMENT OF SHALLOW FOUNDATIONS,†1995.

G. G. Meyerhof, “The ultimate bearing capacity of foundations,†Geotechnique, vol. 2, no. 4, pp. 301–332, 1951.

P. A. Tuan, “A Simplified Formular For Analysis Group Efficiency of Piles in Granular Soil,†vol. 7, no. 7, 2016.

R. Patil, S. Anoor, S. Desai, and M. Kumar, “ANALYSIS AND DESIGN OF RESIDENTIAL BUILDING BY USING SAP-2000,†pp. 2491–2497, 2017.

M. Gen, K. Hu, Y. Yang, S. Mu, and G. Qu, “Procedia Engineering Study on High-rise Structure with Oblique Columns by,†vol. 00, no. 2011, 2012.

Downloads

PlumX Metrics

How to Cite

Candra, A. I. (2018). ANALISIS DAYA DUKUNG PONDASI STROUS PILE PADA PEMBANGUNAN GEDUNG MINI HOSPITAL UNIVERSITAS KADIRI. UKaRsT, 1(1), 27–39. https://doi.org/10.30737/ukarst.v1i1.83

Issue

Section

Articles